Tel : 0756-8818103

Info@crystaldentaltech.com

CoCo International Trading Company

Address:1/F No 41 Ma Wan New Vilage,
Pa Mei Rd,Tung Chung Lantau Island,HongKong

HOME->NEWS CENTER
Reasons for non-fit margin and high occlusion










In porcelain dental restoration, no fitting margin and high occlusion account for a large proportion of reasons for failure of repair and remake. Doctors and technicians have different opinions about these two problems generallyand it is also the focus for them to evade responsibility.

 

A .Margin not fit and high occlusion happens at the same timeand the technicians and doctors think it is the crowns not in positionSo whats reason for not in position?

Firstin clinical aspects

1Doctor Preparation: Abutment not smooth or has fulcrumsirregular

shoulder preparationslight difference in path of insertion. So smooth abutment regular shoulder design and the same path of insertion in preparation should be guaranteed for doctors.




2The coefficient of expansion is not good as water not mixed correctly according to the instructions with the gypsum,so the margin of stone models has gaps to the real one. 3Applying two different kind of gypsum in pouring models. The first layer is superhardonethe second just hard gypsum or common onesso different contraction proportion caused the slight changes of common path of insertion. This will be solved to when same kind gypsum used.

 

4Common gypsum to pour models sometimes cause errors, super hard one is better.



5Not immediately pouring out models after trays gotso the slight shrink of dental impression material caused deviations.

 

 

In the secondfor the technicians

1. Die cutting for restoration is not accuratethere is gaps between die and the baseresults in high occlusion and margin not fit.

SolutionsKeep the clean of the die boxesto check if there is gypsum slag in it or stays in the contacting area of boxes and die. If pins are usedfixation holes should be kept cleanto avoid gypsum slag left in it.




2.Die rockingslight change for common path of insertion.
Solutions:To check if the pins are pasted tight and absolute parallel;if water proportion and solidity of gypsum of the base is suitable;If pin caps used,we should check if they are closed and with appropriate tightness.
 
3.Cutting the contact points of adjacent teeth in die cutting and shape trimmingso the crown can not be fully in position as there isfulcrums.
B. Only margins not fit which mainly caused by models has below reasons
Reasons for doctors
 
1. No gum distinguish line marked and not taking impressions by silicone materials . If gum distinguish line can not reachperiodontalgum distinguish grease can be usedWe can also use aga and alginate material for impressions taken. But doctors should noted that gum distinguish line and accurate impression materials should be used togetheror it is difficult to get afit margin for the ceramic crowns.



 
1. The coefficient of expansion is not good as water is not mixed correctly according to the instructions with the gypsum,so the margin of stone models has gaps to the real margin.
 
2. Not using superhard gypsum for pouring modelscommon gypsum always has deviations.
 
3. Margin has bubbles when pouring models.

NEWS CENTER